1) Lower glass down into cage. Align holes along top of glass
with holes along top edge of cage.
2) Lower top cap with sockets down towards glass and cage.
Pass sockets down through top of glass. Fit edge of top cap
inside glass. Align holes along edge of top cap with holes in
glass and cage.
3) Thread one thumbscrew into each hole along edge of cap
and into holes in cage and glass. IMPORTANT: Insert each
thumbscrew into holes in cap. DO NOT fully tighten each
thumbscrew until all thumbscrews are in place. Once all
thumbscrews are in place, fully tighten each thumbscrew to
secure cap to cage and glass.
4) Pass fixture wire from coupling on top cap through center
tube.
5) Screw center tube onto coupling on top cap.
6) Pass wire from center tube through stem and screw stem to
top of center tube. NOTE: Thread locking compound must be
applied to all stem threads as noted with symbol (3) to
prevent accidental rotation of fixture during cleaning,
relamping, etc.
7) Pass fixture wire through remaining stems and screw stems
together.
8) Pass fixture wire through first loop. Thread first loop onto
end of last stem.
9) Pass fixture wire through second loop and through hole in
canopy.
10) Pass threaded pipe at end of second loop through hole in
canopy.
11) Pass fixture wire through hole in lockwasher. Thread
lockwasher onto end of threaded pipe protruding from
inside canopy.
12) Pass fixture wire through hole in hexnut. Thread hexnut onto
end of threaded pipe.
13) Pass fixture wire through hole in loop at end of safety cable.
Slip loop over end of threaded pipe protruding from inside
canopy.
14) Pass fixture wire through hole in lockwasher. Thread
lockwasher onto end of threaded pipe protruding from
inside canopy.
15) Pass fixture wire through hole in hexnut. Thread hexnut onto
end of threaded pipe.
16) Attach chain link to small loop at end of stem and to loop on
canopy.
17) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF”
position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
18) Find the appropriate threaded holes on mounting strap.
Assemble mounting screws into threaded holes.
19) Attach mounting strap to outlet box. (Screws not provided).
Mounting strap can be adjusted to suit position of fixture.
20) Connect safety cable assembled to canopy to mounting
strap. (This will allow for fixture to be supported while wire
connections are made.)
21) Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a
hole and two raised dimples. Wrap ground wire from
outlet box around green ground screw, and thread into
hole.
B) On fixtures where a cupped washer is provided. Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture
ground wire to outlet box ground wire with wire connector
(not provided.) after following the above steps. Never
connect ground wire to black or white power supply wires.
MOUNTING STRAP
ABRAZADERA DE MONTAJE
CANOPY
ESCUDETE
Date Issued: 9/26/14 IS-43574-US
GREEN GROUND
SCREW
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
KNURL KNOB
PERILLA ESTRADA
3
SMALL LOOP
ARGOLLA PEQUEÑA
3
CHAIN LINK
ESLABÓN DE CADENA
3
STEM
VASTAGO
Were here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAGE
JAULA
GLASS
VIDRIO
22) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
23) Push fixture to ceiling, carefully passing mounting screws
through holes in canopy.
24) Thread knurl knobs onto mounting screws. Tighten knurl
knobs to secure fixture to ceiling.
HEXNUT
TUERCA HEXAGONAL
LOCKWASHER
ARANDELA DE SEGURIDAD
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth)
*Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
CENTER TUBE
TUBO CENTRAL
TOP CAP
TAPA SUPERIOR
THUMBSCREW
TORNILLO DE
MARIPOSA
SOCKET
PORTALÁMPARAS
SAFETY CABLE
CABLE DE
SEGURIDAD
HEXNUT
TUERCA HEXAGONAL
Page view 0
1 2

Summary of Contents

Page 1 - 866-558-5706

1) Lower glass down into cage. Align holes along top of glass with holes along top edge of cage.2) Lower top cap with sockets down towards glass

Page 2

Si la lámpara viene con alambre a tierra. Conecter el alambre a tierra de la lámpara al alambre a tierra de la caja tomacorriente con un con

Comments to this Manuals

No comments