IMPORTANT SAFETY INSTRUCTIONS
LIGHTED BULB IS HOT!
WARNING: To reduce the risk of FIRE or INJURY TO PERSON:
• Turnoffandallowtocoolbeforereplacingbulb.
• BulbgetsHOTQUICKLY!Contactswitchonlywhenturningoff.
• DONOTremaininlightifskinfeelswarm.(Lightisintense,
maycause“sunburn”)
• DONOTlookdirectlyatlightedbulb.
• Keepmaterialsawayfrombulbthatmayburn.
• UseONLYwithwattagespeciedorlower.
• DONOTtouchbulbatanytime,useasoftcloth.Oilfromskin
maydamagebulb.
• DONOToperatexturewithmissingordamagedglass.
1) TURN OFF POWER.
IMPORTANT:Beforeyoustart,NEVERattemptanywork
withoutshuttingofftheelectricityuntiltheworkisdone.
a) Gotothemainfuse,orcircuitbreaker,boxinyour
home.Placethemainpowerswitchinthe“OFF”
position.
b) Unscrewthefuse(s),orswitch“OFF”thecircuitbreaker
switch(s),thatcontrolthepowertothextureorroom
thatyouareworkingon.
c) Placethewallswitchinthe“OFF”position.Ifthexture
tobereplacedhasaswitchorpullchain,placethosein
the“OFF”position.
2) Findtheappropriatethreadedholesonmountingstrap.
Assemblemountingscrewsintothreadedholes.
3) Attachmountingstraptooutletbox.(Screwsnotprovided).
Mountingstrapcanbeadjustedtosuitpositionofxture.
4) Groundinginstructions:(SeeIllus.AorB).
A) Onxtureswheremountingstrapisprovidedwithahole
andtworaisedimples.Wrapgroundwirefromoutlet
boxaroundgreengroundscrew,andthreadintohole.
B) Onxtureswhereacuppedwasherisprovided.Attach
groundwirefromoutletboxundercuppedwasherand
greengroundscrew,andthreadintomountingstrap.
Ifxtureisprovidedwithgroundwire.Connectxture
groundwiretooutletboxgroundwirewithwireconnector.
(Notprovided.)Afterfollowingtheabovesteps.Neverconnect
groundwiretoblackorwhitepowersupplywires.
5) Makewireconnections(connectorsnotprovided.)Reference
chartbelowforcorrectconnectionsandwireaccordingly.
6) Pushxturetowall,carefullypassingmountingscrews
throughholes.
7) Securexturetowallusingthreadedballs.
8) Insertrecommendedbulb.CAUTION: DONOTtouchbulb
withbarehands.Ifthishappens,cleanbulbwithdenatured
alcoholandalintfreecloth.
9) Slipglasssleeveoverbulb.
10) Raisecageuptoxture.Fittopedgeofcageinsideroofof
xture.
11) Fittabonbackofcageinbetweentabsonarmattachedto
canopy.
12) Threadscrewsdownthroughholesinroofandintocage.
Tightenscrewstosecurecagetoroof.
13) Threadscrewthroughholesintabs.Tightenscrewtosecure
xtureinplace.
DateIssued:8/23/13 IS-49467-US
MOUNTINGSTRAP
PLANCHAPARA
MONTAR
CANOPY
ESCUDETE
GREEN GROUND
CUPPED
WASHER
A
B
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
(NOT PROVIDED)
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
GLASSSLEEVE
CAMISADE
VIDRIO
SEE OTHER SIDE FOR SPANISH TRANSLATIONS.
VEA EL OTRO LADO DE TRADUCCIONES AL ESPAÑOL.
BULB
BOMBILLA
THREADEDBALL
BOLAROSCADO
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/
OR IN WET LOCATIONS.
14) Mountingsurfaceshouldbeclean,dry,atand1/4”larger
thatthecanopyonallsides.Anygapsbetweenthemounting
surfaceandcanopyexceeding3/16”shouldbecorrected
asrequired.
15)Withsiliconecaulkingcompound,caulkcompletelyaround
wherebackofcanopymeetsthewallsurfacetoprevent
waterfromseepingintooutletbox.
ROOF
CUBIERTASUPERIOR
TAB
LENGÜETA
ARM
BRAZO
CAGE
JAULA
SCREW
TORNILLO